BACK
- BUILDING STRUCTURES, BUILDINGS AND FACILITIES
- Determination Of The Characteristics Of The Steel-Reinforced Concrete Diaphragm Model Affecting The Result Of The Numerical Experiment
- UDC 697.94 DOI: 10.33622/0869-7019.2022.01.18-25
Linur R. GIMRANOV, e-mail: leenur@mail.ru
Alsou I. FATTAKHOVA, e-mail: fattakhova.alsou@yandex.ru
Kazan State University of Architecture and Engineering, ul. Zelenaya, 1, Kazan 420043, Russian Federation
Abstract. Buildings using a metal frame with steel-reinforced concrete floors are being erected more often. The floor disc's and frame's joint work under the uneven horizontal loads action is ensured by the shear studs setting. In modern design process computational software systems usage is necessary, however, the combined floor using profiled flooring disk model parameters influence on the results accuracy has not been sufficiently studied. So, for example, the optimal stiffness characteristics issue when determining stress-strain state under the horizontal loads action is relevant. This article examines the model various characteristics influence on the efforts determination in flexible stops. On the overlap disk section example modelled in the LIRA-SAPR software package, the anchor rods setting frequency influence, their length, as well as the studs stiffness characteristics influence is considered. It is revealed that only the shear stud simulating bar length influences on the combined floor using profiled flooring anchors calculating force accuracy. The bar's minimum length is determined, at which the result obtained in the calculation in the software package will be reliable. Depending on the stiffness, the bar's maximum length is determined. That is maximum length when the stud works in shear, not in bending. In addition, bar's part modelled as an absolutely rigid body models are considered. As a result, the bar's stiffness characteristics calculation accuracy dependence is obtained, horizontal loaded combined floor using profiled flooring modelling recommendations are given.
Key words: combined flooring, profiled flooring, horizontal loads, bar length, shear stud, anchor. - REFERENCES
1. Baktygulov K. Structures of combined floors with external reinforcement. Nauka i novyye tekhnologii, 2013, vol. 7, pp. 13-17. (In Russian).
2. Xu P., Fu X., Wang C., Xiao T. Proyektirovaniye sovremennykh vysotnykh zdaniy [Design of modern high-rise buildings]. Moscow, АSV Publ., 2008. 469 p. (In Russian).
3. Fattakhova A. I. Impact of horizontal loads on the work of stud bolts in combined floor slabs. Vestnik MGSU, 2020, vol. 15, pp. 31-42. DOI: 10.22227/1997-0935.2020.1.31-42. (In Russian).
4. Ayrumyan E. L., Kamenshchikov N. I., Rumyantseva I. A. Features of the calculation of monolithic plates of steel-reinforced concrete coatings for profiled steel flooring. Promyshlennoye i grazhdanskoye stroitel'stvo, 2015, vol. 9, pp. 21-26. (In Russian).
5. Zamaliev F. S. To the calculation of the interface between the slab and the beam in steel-reinforced concrete structures. Izvestiya KGASU, 2016, vol. 4(38), pp. 222-228. (In Russian).
6. Ayrumyan E. L., Boyarsky A. V. Investigation of the work of a monolithic reinforced concrete slab on a profiled steel deck with transverse bending. Promyshlennoe i grazhdanskoe stroitel'stvo, 2007, no. 10, pp. 30-31. (In Russian).
7. Zamaliev F. S., Ismagilov B. T. Numerical and full-scale studies of anchor ties of steel-reinforced concrete structures. Izvestiya KGASU, 2018, no. 3(45), pp. 121-128. (In Russian).
8. Kolchunov V. I., Dem'yanov A. I., Naumov N. V., Mikhaylov M. M. Calculation of the stiffness of reinforced concrete structures under the action of torsion and bending. IOP Conference Series: Journal of Physics, 2020, vol. 1425, p. 012077. DOI: 10.1088/1742-6596/1425/1/012077.
9. Postanen S. O., Berezkina A. Yu., Komissarov V. V, Postanen M. O. Steel-reinforced concrete floors on profiled steel flooring. Molodoy uchenyy, 2016, vol. 26(130), pp. 74-76. (In Russian).
10. Zamaliev F. S. To the calculation of anchor ties of steel-reinforced concrete structures. Izvestiya KGASU, 2019, vol. 3(49), pp. 87-94. (In Russian).
11. Metallicheskiye konstruktsii. Spetskonstruktsii i sooruzheniya [Metal structures. Special constructions and structures]. Moscow, 2005, vol. 3, pp. 295-303. (In Russian).
12. Jonson R. P. Rukovodstvo dlya proyektirovshchikov k Yevrokodu 4: Proyektirovaniye stalezhelezobetonnykh konstruktsiy EN 1994-1-1 [Designer's guide to Eurocode 4: Design of composite steel and concrete structures EN 1994-1-1]. Moscow, MGSU Publ., 2013. 412 p. (In Russian).
13. Luttrell L., Schultz W., Li D. Diaphragm design manual. Steel Deck Institute. 2015. 294 p.
14. Luttrell L., Pinkham C., Mattingly J., Chen H. North American standard for design of profiled steel diaphragm panels. AISI, 2016. 188 p.
15. Fattakhova A. I. Multi-storey buildings combined floors with different aspect ratios shear stops forces distribution analysis. Izvestiya vuzov. Stroitel'stvo, 2020, vol. 1, pp. 46-56. (In Russian). DOI 10.32683/0536-1052-2020-733-1-46-56.
16. Efimov O. I., Gimranov L. R., Fattakhova A. I. Chekanin M. S. The combined flooring with the profiled flooring usage displacement's determination from horizontal loads. Vestnik BGTU im. V. G. Shukhova, 2021, vol. 9, pp. 37-44. (In Russian). DOI: 10.34031/2071-7318-2021-6-9-37-44.
17. Gimranov L., Fattakhova A. Shear stops forces distribution analysis in combined floors of multi-storey buildings. IOP Conference Series: Materials Science and Engineering, 2020, vol. 890, p. 012080. DOI: 10.1088/1757-899X/890/1/012080.
18. Efimov O., Gimranov L., Fattakhova A. Calculations of the rigidity and the strength of concrete filled steel deck diaphragms. E3S Web of Conferences, 2021, no. 274, p. 03014. DOI: 10.1051/e3sconf/202127403014.
19. Gimranov L. R., Fattakhova A. I. Flexible stop's force determining method in a combined plate using profiled flooring. Vestnik MGSU, 2021, vol. 16(8), pp. 985-993. (In Russian). DOI: 10.22227/1997-0935.2021.8.
20. Eremin V. G., Kozlov A. V. Analytical dependences taking into account the shift between reinforced concrete and steel structural elements of bridges in continuous multi-span beams. Nauchnyy zhurnal stroitel'stva i arkhitektury, 2019, vol. 4(56), pp. 109-120. (In Russian).
21. Kozlov A. V., Kozlov V. A. Stress-strain state of a composite structure taking into account the shear compliance between a reinforced concrete slab and a steel beam. Stroitel'naya mekhanika i konstruktsii, 2021, vol. 2(29), pp. 48-61. (In Russian).
22. Konin D. V., Krylov A. S., Chesnokov D. A. Assessment of test results for angle anchor stops for shear action. Stroitel'naya mekhanika i konstruktsii, 2021, vol. 2(295), pp. 16-26. (In Russian). DOI 10.37538/0039-2383.2021.2.16.26.
23. Konin D. V., Vedyakov I. I., Krylov A. S. et al. Metodicheskiye rekomendatsii po raschetu i proyektirovaniyu stalezhelezobetonnykh perekrytiy [Methodological recommendations for the calculation and design of steel-reinforced concrete floors]. Moscow, NITS Stroitelstvo Publ., 2018. 63 p. (In Russian).
24. Richter D. A., Iovenko A. A., Ershov M. N. Design of steel-reinforced concrete floors on steel profiled decking using anchor stops HILTI X-HVB. Tekhnologiya i organizatsiya stroitel'nogo proizvodstva, 2013, vol. 4(5), pp. 17-22. (In Russian). - For citation: Gimranov L. R., Fattakhova A. I. Determination of the Characteristics of the Steel-Reinforced Concrete Diaphragm Model Affecting the Result of the Numerical Experiment. Promyshlennoe i grazhdanskoe stroitel'stvo [Industrial and Civil Engineering], 2022, no. 1, pp. 18-25. (In Russian). DOI: 10.33622/0869-7019.2022.01.18-25.